4°C Blood Bank Refrigerator REF23-208
Designed as an essential piece of equipment in the immunohematology department and provides safe and convenient storage of whole blood, blood components, reagents and ensures freshness and integrity of blood and blood components. Microprocessor integrated system provides excellent temperature accuracy and reliable performance.
Used in Immunohematology Department, Blood Bank, Laboratory, Research, Medical, Pharmaceutical
Also known as Laboratory Blood Bank Refrigerator
- Microprocessor controlled forced-air cooling with electrical heat compensation system
- Digital temperature display for upper and lower sections in chamber with 0.1°C resolution
- Consistent cabinet temperature 2-6°C
- High-tech integrated sensors to display and control temperature
Features
- Microprocessor controlled forced-air cooling with electrical heat compensation system
- Digital temperature display for upper and lower sections in chamber with 0.1°C resolution
- Consistent cabinet temperature 2-6°C
- High-tech integrated sensors to display and control temperature
- Auto-defrost to remove moisture on cooling surface
- Build-in backup battery to display temperature and to operate audible and visual alarm systems for up to 72 hours without ac power
- Equipped with a complete temperature alarm system featuring audible buzzer and visible flashing light
- Standard with laser printer
- Standard with acrylic inner small door, for less affection on other room when one door open
- Safety lock to prevent unauthorized access
- Storage space designed for easy sorting of a variety of blood products
Specifications
Capacity | 208 L |
Temperature Range | 4°C±1 |
Ambient Temperature | 10~32 °C |
Refrigerant | R134a, CFC free |
Defrost Method | Auto Defrost |
Controller | Microprocessor Control with digital Display |
Cooling Type | Forced air cooling |
Compressor | Embraco/1 |
Evaporator | Finned evaporator |
Evaporator material | Copper pipe and aluminum fin |
Condenser | Wire-and-tube |
Sensor | NTC |
Alarms | High/low temperature, Power off, Temperature controller malfunction, Backup battery malfunction, Backup battery Alarm for power off (72h) |
Insulation | PURF |
Material | Inside: Stainless steel |
Outside: | |
Color sprayed steel | Shelves |
Shelves | Mode of Condenser |
51.2 dB | Internal Size |
432x462x978 mm | External Size |
522x600x1550 mm | Package Size |
572x685x1570 mm | Accessories |
Caster, Test hole 1/25MM, Thermal printer | Optional Accessories |
Temperature recorder | Weight |
67 / 75 kg | Power consumption (kW.h/24h) |
2.22 kWh/24hrs | Power |
200 W | Power Supply |